Adaptor Flanges for Mining MA/FT, MA/TF and MA/B



Application
For converting the method of gland entry to match that of the enclosure.
Standards/Approvals
Designed and approved to BS 4683 (part 2); and BS 5501 (Parts 1 and 5).
FLP Certificate No's Adaptors MA/FT, MA/TF: 865015 U. Blanking Plug MA/B: 865016 U.
Fitting Instructions
MA/FT - Tighten onto the gland then bolt the enclosure.
MA/TF - Tighten into the enclosure then bolt gland onto the adaptor.
MA/B - Bolt directly to the enclosure.
Note: Before bolting make sure mating faces are clean.
IP Ratings
IP54 as normally supplied but can be made up to IP66 with suitable sealing washers between gland and adaptor and enclosure
Type
MA/FT - To match a threaded gland to a spigot entry enclosure
MA/TF - To match a spigotted gland to a threaded entry enclosure.
MA/B - To blank off spare spigot entries on the enclosure.
Note: Before bolting always ensure mating faces are clean.
|
Adaptor Size |
Thread |
Spigot |
Bore |
Bore |
Width |
Centres |
|
||||||||||||||
|
20S |
20 |
19.05 |
11.7 |
19.15 |
27 |
44.45 |
12.7 |
M6x1.0 |
6.6 |
11.5 |
7.0 |
||||||||||
|
20 |
20 |
19.05 |
14.0 |
19.15 |
32 |
44.45 |
12.7 |
M6x1.0 |
6.6 |
11.5 |
7.0 |
||||||||||
|
25 |
25 |
25.40 |
20.2 |
25.50 |
39 |
57.15 |
12.7 |
M6x1.0 |
6.6 |
11.5 |
7.0 |
||||||||||
|
32 |
32 |
31.75 |
26.5 |
31.85 |
45 |
69.85 |
14.3 |
M8x1.25 |
9.0 |
15.5 |
8.7 |
||||||||||
|
40 |
40 |
38.10 |
32.4 |
38.20 |
52 |
82.55 |
14.3 |
M8x1.25 |
9.0 |
15.5 |
8.7 |
||||||||||
|
*Note: Dimension 'S' has a tolerance of +0.00 to -0.07mm |
|||||||||||||||||||||