FITTING INSTRUCTIONS
1.
Seperate gland into its three component parts
and after ensuring that the seal is in
its relaxed state, pass item 3 over the cable.
2. Strip back outer sheath and armour to suit
equipment geometry.
3. Expose armouring by further stripping outer
sheath for a length equivalent to the
item 2 knurl plus 10mm and splay out
the outer armour wires.
4. Remove the inner-armour insulation up
to the splay position, then
pass item 2 over the
cable to butt against the outer armour.
5. Secure Item 1 into the equipment.
6. Pass cable through item 1, equally spacing
armoured wires on knurled cone.
7. Lock inner armouring by tightening item
2 onto item 1.
8. Equally space the outer armour wires
on the knurled cone of item 2,
then
lock outer armouring by
tightening item
3 onto item 2.
Note: Items 1,2 and
3 should not lock face to
face.
9. Close seal by tightening second hexagon
of item 2.
|

See dimensions
table below |