Adaptor Flanges for Mining
MA/FT, MA/TF and MA/B
 

    APPLICATION  

   For converting the method of gland
     entry to match that of the enclosure.

    TYPE

   MA/FT - To match a threaded gland to
     a spigot entry enclosure
   MA/TF - To match a spigotted gland to
     a threaded entry enclosure.
   MA/B - To blank off spare spigot entries       on the enclosure.
      Note: Before bolting always ensure       mating faces are clean.



   FITTING INSTRUCTIONS

   MA/FT - Tighten onto the gland then
     bolt the enclosure.
   MA/TF - Tighten into the enclosure then
      bolt gland onto the adaptor.
   MA/B - Bolt directly to the enclosure.
      Note: Before bolting make sure mating       faces are clean.


   STANDARDS/APPROVALS

   Designed and approved to BS 4683       (part 2); and BS 5501 (Parts 1 and 5).
   FLP Certificate No's
     Adaptors MA/FT, MA/TF: 865015 U.
     Blanking Plug MA/B: 865016 U.



   IP RATING

   IP54 as normally supplied but can be      made up to IP66 with suitable sealing      washers between gland and adaptor
     and enclosure








See dimensions table below
Adaptor
Size
Thread
Dia.
'C'

Spigot
Dia.
'S'

Bore
Dia.
'A'
Bore
Dia.
'B'
Width
'W'
Centres
'L'
Mounting Dimensions
Rad.R Dia.'G' Dia. 'H' Dia. 'J' C'bore 'K'
20S
20
19.05
11.7
19.15
27
44.45
12.7
M6x1.0
6.6
11.5
7.0
20
20
19.05
14.0
19.15
32
44.45
12.7
M6x1.0
6.6
11.5
7.0
25
25
25.40
20.2
25.50
39
57.15
12.7
M6x1.0
6.6
11.5
7.0
32
32
31.75
26.5
31.85
45
69.85
14.3
M8x1.25
9.0
15.5
8.7
40
40
38.10
32.4
38.20
52
82.55
14.3
M8x1.25
9.0
15.5
8.7

*Note: Dimension 'S' has a tolerance of +0.00 to -0.07mm
          Dimension 'B' has a tolerance of +0.07 to -0.00mm

DETAILS OF LARGER SIZES (UP TO 75mm) - ON REQUEST

All Dimensions in millimetres unless otherwise stated.